Sharp ph 51

Can anybody give me a website where I can get the operating instructions? Really all I need is to know which way to turn the top screws and what each of them are for specifically. Thanks.
Reply With Quote
  #2 (permalink)  
Old Feb-09-2010, 08:12
Registered+
 
Join Date: Feb-02-2007
Posts: 1,654
LOC NAR on probation has disabled reputation
It's made by Milwaukie. Maybe why I had a hard time finding it too.


CONDITIONING:
Remove the cap and immerse the pH51 in
MA9015 storage solution for 2 hours to activate
the electrode.
CALIBRATION:
Unscrew the battery compartment cap on the
top of the meter and perform one of the following
two-point calibration procedure, according
to the required application:
Acid calibration for measurements below pH7:
• Immerse the electrode in pH7.01
(M10007) buffer solution.
• Allow the reading to stabilize and
with a small screwdriver turn the
“7” calibration trimmer inside the
battery compartment until the display
shows "7.0".
• Rinse the electrode with tap water
and immerse it in pH4.01 (M10004)
buffer solution.
• Allow the reading to stabilize and with a
small screwdriver turn the “4” calibration trimmer
until the display shows "4.0".
Alkaline calibration for measurements above pH7:
• Immerse the electrode in pH7.01 (M10007)
buffer solution.
• Allow the reading to stabilize and with a
small screwdriver turn the “7” calibration trimmer
until the display shows "7.0".
• Rinse the electrode with tap water and immerse
it in pH10.01 (M10010) buffer solution.
• Allow the reading to stabilize and with a
small screwdriver turn the “4” calibration trimmer
until the display shows "10.0".
Replace the battery compartment cap.
OPERATION:
• Remove the protective cap.
• Turn the pH51 on by pressing the ON key.
• Immerse the electrode in the solution to be
tested.
• Stir gently and wait for the reading
to stabilize.
• After use, rinse the electrode with
water to minimize contamination.
• Store the electrode with a few
drops of storage (MA9015) or pH7
(M10007) solution in the protective
cap.
• Always replace the protective cap after use.
NEVER USE DISTILLED OR DEIONIZED WATER
FOR STORAGE PURPOSES.
ELECTRODE REPLACEMENT:
The electrode can be easily replaced
in the following way:
• Remove the protective cap.
• Unscrew the plastic ring on the
top of the electrode.
• Pull out the MA73600 pH electrode
and replace it with a new
one (aligning the colored pin towards
the LCD side).
• Make sure the gaskets are in place
before screwing back the ring.
BATTERY REPLACEMENT:
pH51 is supplied with BEPS (Battery Error Preventing
System) which avoids any erroneous
reading due to low battery level, by switching the
meter off. To replace the batteries unscrew the
battery compartment cap and replace all three
1.5V batteries while paying attention to their polarity.
Make sure the gasket is in place before
screwing back the cap.
Batteries should only be replaced in a nonhazardous
area using the battery type specified in
this instruction manual.
WARRANTY:
This meter is warranted from all defects in materials and manufacturing
for a period of two years. The electrode is warranted for a period of
one year. During this period, the required repair or replacement of parts,
where the damage is not due to negligence or erroneous operation by the
user, will be effected free of charge.
Reply With Quote
  #3 (permalink)  
Old Feb-09-2010, 08:47
Rubberbubbler's Avatar
Registered+
 
Join Date: May-26-2009
Posts: 231
Rubberbubbler is just really niceRubberbubbler is just really niceRubberbubbler is just really niceRubberbubbler is just really niceRubberbubbler is just really niceRubberbubbler is just really niceRubberbubbler is just really nice
Good luck with that Ph 51. I went through 3 in 4 months They would not calibrate after a couple of weeks or the screws in the top would strip. I hope its just me.
__________________
http://boards.cannabis.com/grow-log/...unk-train.html

Lucky to be born on 420
Reply With Quote
  #4 (permalink)  
Old Feb-09-2010, 12:12
Registered
 
Join Date: Jan-23-2010
Posts: 2
soarsalone is an unknown quantity at this point
Thank you for the quick reply! appreciate it.
Reply With Quote
Reply

Bookmarks

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are Off
Refbacks are On



All times are GMT -5. The time now is 04:31.


 
Page generated in 0.10660 seconds with 8 queries